Expro Excellence
Meters
Customer upgrades clamp-on metering
Objectives
  • A major operator approached Expro looking for a metering solution for the produced water overboard line on a North Sea platform
  • To meet OSPAR regulations the customer needed ot upgrade their existing in-line metering
  • The customer intitially installed other flow meter types:
    • In line mag meter
    • Clamp on ultrasonic meter
    • Both meters provide unreliable flow measurements due to the high salinity, conductiivity and the presence of oil, fine sand and dissolved gas
    • Expro provided a non-intrusive permanent metering solution which had a measurement accuracy of (± 2%) which was well within the customer's requirements
Expro Excellence
  • Our customer was cautious in purchasing a third meter, Expro provided an ActiveSONAR ™ flow meter initially on a temporary surveillance basis.  The meter was clamped onto the pipe downstream of the pipe reducer and also positioned upstream on the in-line magnetic flow meter and on the flow line control valve, non ideal flow conditioning
  • There was no adverse effect on the ActiveSONAR™ meter measurement due to the salinity, solids and or oil.  Expro's flow studio diagnostics demonstrated the presence of entrained air from the pumps
  • Subsequently the flow meter was integrated into the platform DAQ system to provide real time data
Value to client
  • Expro's ActiveSONAR™ meter provided a successful solution in providing metering where mulitiple flow meter types had failed previously
  • The customer was satisfied with the data provided onsite during the surveillance and decided to purchase the meter
  • The customer met OSPAR regulations with a measurement accuracy ± 2%
Contact

Customer upgrades clamp-on metering

In Brief
Product Line
Meters
Region
Europe CIS
Objectives
  • A major operator approached Expro looking for a metering solution for the produced water overboard line on a North Sea platform
  • To meet OSPAR regulations the customer needed ot upgrade their existing in-line metering
  • The customer intitially installed other flow meter types:
    • In line mag meter
    • Clamp on ultrasonic meter
    • Both meters provide unreliable flow measurements due to the high salinity, conductiivity and the presence of oil, fine sand and dissolved gas
    • Expro provided a non-intrusive permanent metering solution which had a measurement accuracy of (± 2%) which was well within the customer's requirements
Expro Excellence
  • Our customer was cautious in purchasing a third meter, Expro provided an ActiveSONAR ™ flow meter initially on a temporary surveillance basis.  The meter was clamped onto the pipe downstream of the pipe reducer and also positioned upstream on the in-line magnetic flow meter and on the flow line control valve, non ideal flow conditioning
  • There was no adverse effect on the ActiveSONAR™ meter measurement due to the salinity, solids and or oil.  Expro's flow studio diagnostics demonstrated the presence of entrained air from the pumps
  • Subsequently the flow meter was integrated into the platform DAQ system to provide real time data
Value to client
  • Expro's ActiveSONAR™ meter provided a successful solution in providing metering where mulitiple flow meter types had failed previously
  • The customer was satisfied with the data provided onsite during the surveillance and decided to purchase the meter
  • The customer met OSPAR regulations with a measurement accuracy ± 2%
Contact

For further information, please contact:

nigel.webster@exprogroup.com